SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Figure 7.13-4
Figure 7.13-5
Only for 500SP and 700SP models.
Figure 7.13-6
7. Back off the lock-nut (g) and back off the
screw (h) of the rear tensioning mechanism,
using a 17mm wrench.
8. Back off the screw (i), using an 8mm
wrench, and remove the rear tensioning
mechanism assembly.
9. Back off the screws (l) securing the two
bridge bearings on which the secondary shaft
is assembled, using an 8mm hexagonal
wrench for the screws and a 17mm wrench to
hold the corresponding nuts in place.
10. Remove the secondary shaft assembly,
pulling it out from the belt.
11. Cut the strip tie and unplug the three faston
circled in the figure at left.
Continued on following page