9.5.1.4.

Table of configuration parameters

To correctly display the parameter values, you need to load them from the low kit, using the
"Read from low kit" function.
To change the setting, press the CHANGE key and insert the value using the numeric keyboard.
Press ENTER key to confirm or BACK key to back forward.
After any changes to the parameter values, you need to load them in the low kit using the
"Write to low kit" function.
Parameter
Description
Par 01
Transmission ratio
Par 02
Speed ratio (integer part)
Par 03
Minimum braking current (standby pos.) [mA]
Par 04
Maximum continuous power [W]
Par 05
Machine torque correction coefficient (constant torque)
Par 06
User friction torque
Par 07
Maximum coil temperature [°C]
Par 08
Minimum revolutions [RPM]
Par 09
RPM integration scale
Par 10
Filter threshold [RPM]
Par 11
Speed ratio (decimal part)
Par 12
User friction torque delta
Par 13
NOT USED
Press HOME to confirm and save, FORWARD or BACK to scroll the pages.
Pagina 9.32
SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Default values
141
1
0
200
100
60
125
35
1
75
60
10
0