SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
6.10. THERE IS NO RESISTANCE
The machine will not produce resistance if:
• the display board is not receiving a speed signal;
• the brake board is not generating current;
• the brake is defective.
Replace
ELT-02 cable
THERE IS NO
RESISTANCE
Are the Watt and SPM v alues
shown on the display dif f erent
f rom zero?
Does the brake board supply
tension at the brake?
Is the resistance on the Brake
winding
more or less 5 Ohm?
NO
Does the input of brake receiv e
tension f rom the brake?
NO
YES
1
NO
YES
2
NO
YES
3
YES
Carry out the "The speed
signal is incorrect"
troubleshooting procedure
Replace the brake board
Replace the brake
Replace the brake
Page 6.27