10.2. MECHANICAL SAFETY TESTS

10.2.1.
C
HECKING THE ASSEMBLY OF THE TRANSMISSION AND LEVERS SYSTEMS
Check the correct assembly of the: levers, footboards and brake components. In particular, make
sure that:
The bearings have been correctly mounted.
The footboard levers have been correctly mounted and aligned. Try to exercise on the machine
and check the movement is smoothly and do not produce noise;
The hand levers have been correctly mounted and aligned. Try to exercise on the machine and
check the movement is smoothly and do not produce noise;
The drive-belt is in good condition and correctly assembled on the pulleys. That the drive-belt
and pulleys do not produce any unusual noise when the user pedals, even at a high effort level.
The brake winding components are correctly assembled. That the pedaling action is always
smooth and silent, even at high effort level.
10.2.2.
C
HECKING THE ASSEMBLY OF THE GUARDS
Check the assembly of the machine guards, making sure that:
They are all in place and correctly secured so that no parts of the machine are left exposed that
may cause injury to the user.

10.3. START-UP CHECK

Following installation and after every technical intervention on the machine, plug it into a power
outlet, set the power switch to ON.
On power-up the machine performs a self test of the upper and lower assemblies. At the end of this
the machine goes into standby, awaiting a keyboard command.
To check the correct operation of the machine:
get on the machine;
begin exercising;
check that the displayed speed varies accordingly;
check that the exercise resistance varies when the "+" and "-" keys and the touch sensor are
pressed and the effort level change from 1 to 25;
put on the heart rate meter and check that the machine correctly reads the heart rate value;
grasp the sensors and check that the machine correctly reads the heart rate value.