A.2 System alarms
Number
Effect/cause
160014
Only one OPC server project can be started on a
PC/MP. An alarm is output when an attempt is
made to start a second project.
The second project has no OPC server functionality
and cannot be located as an OPC server by
external sources.
170000
S7 diagnostics events are not indicated because it
is not possible to log on to the S7 diagnostics
functions at this device. The service is not
supported.
170001
The S7 diagnostics buffer cannot be viewed
because communication with the controller is shut
down.
170002
The S7 diagnostics buffer cannot be viewed
because reading of the diagnostics buffer (SSL)
was canceled with error.
170003
An S7 diagnostics event cannot be visualized. The
system returns internal error %2.
170004
An S7 diagnostics event cannot be visualized. The
system returns an internal error of error class %2,
error number %3.
170007
It is not possible to read the S7 diagnostics buffer
(SSL) because this operation was canceled with an
internal error of class %2 and error code %3.
180000
A component/OCX received configuration data with
a version ID which is not supported.
180001
System overload because too many actions
running in parallel. Not all the actions can be
executed, some are rejected.
180002
The on-screen keyboard could not be activated.
Possible causes:
"TouchInputPC.exe" was not registered due to a
faulty Setup.
190000
It is possible that the tag is not updated.
190001
The tag is updated after the cause of the last error
state has been eliminated (return to normal
operation).
190002
The tag is not updated because communication
with the controller is down.
190004
The tag is not updated because the configured tag
address does not exist.
190005
The tag is not updated because the configured
controller type does not exist for this tag.
190006
The tag is not updated because it is not possible to
map the controller type in the data type of the tag.
162
Remedy
Do not start a second project with OPC server
functionality on the computer.
-
Set the controller to online mode.
-
-
-
-
Install a newer component.
Several remedies are available:
Increase the configured cycle times or basic clock.
Generate the alarms at a slower rate (polling).
Initiate scripts and functions at greater intervals.
If the alarm appears more frequently:
Restart the HMI device.
Reinstall WinCC flexible Runtime.
-
-
Select the system function "SetOnline" to go online.
Check the configuration.
Check the configuration.
Check the configuration.
OP 73micro, TP 177micro (WinCC flexible)
Operating Instructions, 09/2007, 6AV6691-1DF01-0AB0