Table of Contents

Advertisement

3. Press
Result
The Loader appears again.
Note
When restarting the system, a project may already be loaded on the HMI device. The system
then skips transfer mode and starts the project.
Use the relevant operator control object to close the project.
Further information on this may be available in your plant documentation.
Navigating in the Loader
Button
ENTER
HELP
ESC
Function test
Perform a function test following commissioning. The HMI device is fully functional when one
of the following states is indicated:
● The "Transfer" dialog is displayed.
● The Loader is displayed.
● A project is started.
Switching off the HMI device
Options for switching off the HMI device:
● Switch off the power supply.
● Disconnect the terminal block from the HMI device.
OP 73micro, TP 177micro (WinCC flexible)
Operating Instructions, 09/2007, 6AV6691-1DF01-0AB0
The HMI device automatically sets transfer mode during initial startup if it does no contain
any project data yet. The following dialog appears:
Transfer
Connecting to host.
Figure 4-10
"Transfer" dialog
HELP
to cancel the transfer.
ESC
+/–
TAB
or
4.2 Mounting and connecting the OP 73micro
Action
Press one of these cursor keys to select the next entry in arrow
direction.
The input is confirmed.
The submenu or dialog shown below opens.
Move back
Returns to the next higher menu layer.
Cancel transfer mode
Mounting and connection
47