Update The Dmi/Smbios Data - Lenovo thinksystem SR630 Maintenance Manual

Hide thumbs Also See for thinksystem SR630:
Table of Contents

Advertisement

The external BMC (Lenovo XClarity Controller) LAN IP address. There is no default
value. This parameter is required.
bmc_user_id
The BMC (Lenovo XClarity Controller) account (1 of 12 accounts). The default value is
USERID.
bmc_password
The BMC (Lenovo XClarity Controller) account password (1 of 12 accounts). The default
value is PASSW0RD (with a zero 0 not an O).
Example that does not use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SYsInfoUUID <uuid_value>
[−−bmc bmc_user_id:bmc_password@bmc_internal_ip]
Example that does use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
Step 3.
Restart the Lenovo XClarity Controller.
Step 4.
Restart the server.

Update the DMI/SMBIOS data

The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use the
Lenovo XClarity Essentials OneCLI to update the DMI in the UEFI-based server. Lenovo XClarity Essentials
OneCLI is an online tool that supports several operating systems; make sure that you download the version
for your operating system.
Notes: You can use Lenovo XClarity Provisioning Manager to update the asset tag for the server:
1. Start the server and press F1 to display the Lenovo XClarity Provisioning Manager system setup
interface.
2. From the System Summary page, click Update VPD.
3. Update the asset tag information.
To download Lenovo XClarity Essentials OneCLI, go to the following site:
https://datacentersupport.lenovo.com/us/en/solutions/HT116433
Lenovo XClarity Essentials OneCLI sets the DMI in the Lenovo XClarity Controller. Select one of the following
methods to access the Lenovo XClarity Controller and set the DMI:
• Online from the target system, such as LAN or keyboard console style (KCS) access
• Remote access to the target system (LAN based)
Step 1.
After you haveLenovo XClarity Essentials OneCLI in place, type the following commands to set the
DMI:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
The server machine type and model number. Type mtm xxxxyyy, where xxxx is the machine
type and yyy is the server model number.
<s/n>
The serial number on the server. Type sn zzzzzzz, where zzzzzzz is the serial number.
136
ThinkSystem SR630 Maintenance Manual