When enabled, the SQI instruction compares a Source element through a Mask
to an Array element for equality.
Typically use the same CONTROL structure as the SQO and SQL instructions.
The SQI instruction operates on contiguous memory.

Enter an Immediate Mask Value

When you enter a mask, the programming software defaults to decimal values. If
you want to enter a mask by using another format, precede the value with the
correct prefix.
Prefix
16#
8#
2#
Not affected
None
Sequencer Instructions (SQI, SQO, SQL)
Description
Hexadecimal
For example; 16#0F0F
Octal
For example; 8#16
Binary
For example; 2#00110011