Allen-Bradley Logix5000 Reference Manual page 204

1756 controllogix, 1768 compactlogix, 1769 compactlogix, 1789 softlogix, 1794 flexlogix, powerflex 700s with drivelogix
Hide thumbs Also See for Logix5000:
Table of Contents

Advertisement

Chapter 4
Input/Output Instructions (MSG, GSV, SSV, IOT)
Attribute
Data Type
NAKReceiveLimit
SINT
NormalPollGroupSi
INT
ze
PollingMode
SINT
ReplyMessage
DINT
Wait
SlavePollTimeout
DINT
StationAddress
INT
TokenHoldFactor
SINT
TransmitRetries
SINT
PendingACK
DINT
Timeout
Pending
SINT
Duplicate
Detection
Pending
SINT
Embedded
ResponseEnable
PendingEnable
SINT
StoreFwd
PendingENQ
SINT
TransmitLimit
PendingEOT
SINT
Suppression
PendingError
SINT
Detection
PendingMaster
SINT
Message
Transmit
PendingMax
SINT
StationAddress
PendingNAK
SINT
ReceiveLimit
PendingNormal
INT
PollGroupSize
PendingPolling
SINT
Mode
204
Instruction
Description
GSV
The number of NAKs received in response to a message before stopping transmission (point-to-
point communication only). Valid value 0...127. Default is 3.
GSV
Number of stations to poll in the normal poll node array after polling all the stations in the priority
poll node array (master only).
Valid value 0...255. Default is 0.
GSV
Current polling mode (master only). Default setting is 1.
Value
Meaning
0
Message-based, but don't allow slaves to initiate messages
1
Message-based, but allow slaves to initiate messages (default)
2
Standard, single-message transfer per node scan
3
Standard, multiple-message transfer per node scan
GSV
The time (acting as a master) to wait after receiving an ACK before polling the slave for a
response (master only). Valid value 0...65,535. Delay in counts of 20 msec periods. The default is 5
periods (100 msec).
GSV
The amount of time in msecs that the slave waits for the master to poll before the slave declares
that it is unable to transmit because the master is inactive (slave only). Valid value 0...32,767.
Delay in counts of 20 msec periods. The default is 3000 periods (1 minute).
GSV
Current station address of the serial port. Valid value 0...254. Default is 0.
GSV
Current value (1...4) of the maximum number of messages sent by this node before passing the
token on a DH-485 network. Default is 1.
GSV
Number of times to resend a message without getting an acknowledgment (master and slave
only).
Valid value 0...127. Default is 3.
SSV
Pending value for the ACKTimeout attribute.
SSV
Pending value for the DuplicateDetection attribute.
SSV
Pending value for the EmbeddedResponse attribute.
SSV
Pending value for the EnableStoreFwd attribute.
SSV
Pending value for the ENQTransmitLimit attribute.
SSV
Pending value for the EOTSuppression attribute.
SSV
Pending value for the ErrorDetection attribute.
SSV
Pending value for the MasterMessageTransmit attribute.
SSV
Pending value for the MaxStationAddress attribute.
SSV
Pending value for the NAKReceiveLimit attribute.
SSV
Pending value for the NormalPollGroupSize attribute.
SSV
Pending value for the PollingMode attribute.
Rockwell Automation Publication 1756-RM003N-EN-P - October 2011