Allen-Bradley Logix5000 Reference Manual page 338

1756 controllogix, 1768 compactlogix, 1769 compactlogix, 1789 softlogix, 1794 flexlogix, powerflex 700s with drivelogix
Hide thumbs Also See for Logix5000:
Table of Contents

Advertisement

Chapter 7
Move/Logical Instructions (MOV, MVM, BTD, MVMT, BTDT, CLR, SWPB, AND, OR, XOR, NOT, BAND, BOR, BXOR, BNOT)
Description:
Arithmetic Status Flags:
Fault Conditions:
Condition
Prescan
Instruction first scan
Instruction first run
EnableIn is cleared
EnableIn is set
Postscan
338
The BXOR instruction performs an exclusive OR on two boolean inputs.
Out = In1 XOR In2
Not affected
None
Execution:
Function Block Action
No action taken.
No action taken.
No action taken.
EnableOut is cleared.
The instruction executes.
EnableOut is set.
No action taken.
Rockwell Automation Publication 1756-RM003N-EN-P - October 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents