Input Parameter
Data Type
HEnabled
BOOL
LEnabled
BOOL
LLEnabled
BOOL
AckRequired
BOOL
ProgAckAll
BOOL
OperAckAll
BOOL
HHProgAck
BOOL
HHOperAck
BOOL
HProgAck
BOOL
HOperAck
BOOL
LProgAck
BOOL
LOperAck
BOOL
LLProgAck
BOOL
LLOperAck
BOOL
FactoryTalk Alarms and Events Logix-based Instructions (ALMD, ALMA)
Description
High alarm condition detection. Set to enable detection of the High alarm condition. Clear to disable
detection of the High alarm condition.
Default is set.
Low alarm condition detection. Set to enable detection of the Low alarm condition. Clear to disable
detection of the Low alarm condition.
Default is set.
Low Low alarm condition detection. Set to enable detection of the Low Low alarm condition. Clear to
disable detection of the Low Low alarm condition.
Default is set.
Specifies whether alarm acknowledgement is required. When set, acknowledgement is required. When
cleared, acknowledgement is not required and HHAcked, HAcked, LAcked, LLAcked, ROCPosAcked, and
ROCNegAcked are always set.
Default is set.
Set by the user program to acknowledge all conditions of this alarm. Requires a cleared-to-set transition
while the alarm conditions are unacknowledged.
Default is cleared.
Relay Ladder
Copied from the instruction operand.
Structured Text
Copied from the instruction operand.
Set by the operator interface to acknowledge all conditions of this alarm. Requires a cleared-to-set
transition while the alarm conditions are unacknowledged. The alarm instruction clears this parameter.
Default is cleared.
High High program acknowledge. Set by the user program to acknowledge a High High condition. Requires
a cleared-to-set transition while the alarm condition is unacknowledged.
Default is cleared.
High High operator acknowledge. Set by the operator interface to acknowledge a High High condition.
Requires a cleared-to-set transition while the alarm condition is unacknowledged. The alarm instruction
clears this parameter.
Default is cleared.
High program acknowledge. Set by the user program to acknowledge a High condition. Requires a cleared-
to-set transition while the alarm condition is unacknowledged.
Default is cleared.
High operator acknowledge. Set by the operator interface to acknowledge a High condition. Requires a
cleared-to-set transition while the alarm condition is Unacknowledged. The alarm instruction clears this
parameter.
Default is cleared.
Low program acknowledge. Set by the user program to acknowledge a Low condition. Requires a cleared-
to-set transition while the alarm condition is unacknowledged.
Default is cleared.
Low operator acknowledge. Set by the operator interface to acknowledge a Low condition. Requires a
cleared-to-set transition while the alarm condition is unacknowledged. The alarm instruction clears this
parameter.
Default is cleared.
Low Low program acknowledge. Set by the user program to acknowledge a Low Low condition. Requires a
cleared-to-set transition while the alarm condition is unacknowledged.
Default is cleared.
Low Low operator acknowledge. Set by the operator interface to acknowledge a Low Low condition.
Requires a cleared-to-set transition while the alarm condition is unacknowledged. The alarm instruction
clears this parameter.
Default is cleared.