Setting Response Time - V
Averaging
Procedure Options
Initializing Setup
Parameters - Default
Setup
Procedure Options
1-18
Use this option to specify the number of readings that occur before
the meter will respond to a step change in flow rate. In general, the
smaller the number of readings, the less steady the display will
appear. Complete the following steps to set the response time:
IMPORTANT:
Do not change this number unless instructed to do so
by GE Infrastructure Sensing personnel.
1. Open the SITE EDIT MENU from the Edit Functions menu.
2. Select Channelx.
3. Select Set up.
4. Select V Averaging.
5. Select the response time (in seconds) from the pull-down menu
and press Next Item/Enter. For best results, select 30 to ensure the
most stable signal.
After completing the above steps, IDM returns to the Channel SET UP
window. Do one of the following:
To continue programming, refer to Appendix A, Menu Maps
for IDM, to navigate to the desired menu.
To leave the User Program, press Exit Page three times.
Use this option to initialize (reset) all of the parameters within the
up
menu to their default values. Complete the following steps to reset
all of the parameters:
1. Open the SITE EDIT MENU from the Edit Functions menu.
2. Select Channelx.
3. Select Set up.
4. Select Default Setup.
5. Select Yes to initialize parameters or No to abort this command.
After completing the above steps, IDM returns to the Channel Set up
window. Do one of the following:
To continue programming, refer to Appendix A, Menu Maps
for IDM, to navigate to the desired menu.
To leave the User Program, press Exit Page three times.