GE XGS868 Programming Manual page 32

Steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

Selecting Error Handling
(cont.)
Procedure Options
Programming Site Data
7. Use the pull-down menu to enable or disable 2-path error
handling. Specific responses of the display and the totalizer are
listed in Table 1-8 below.
2-path error handling
The
two sets of transducers are installed in the same location in the
same pipe to improve accuracy and the meter is operated in
mode. With this function enabled, the Model XGS868 performs
error handling only if both channels are in error. If this function is
disabled, error handling occurs when either channel goes into
error.
Table 1-7: Error Response Options
Option
Output Response
Hold Last
Holds the last "good"
Value
reading.
Forces the outputs to
Force Low
the low set point.
Forces the outputs to
Force High
the high set point.
Forces the outputs
Force High
≈10% above the high
High
set point.
Error Level
Forces outputs to
in mA
entered mA level.
Table 1-8: 2-Path Error Response Options
Option
Display Response
Displays the average of
Channel1 and Channel2,
No
regardless of the error state
of either channel.
1. If one channel is in error,
the other channel's value
is displayed as the
Yes
average.
2. If both channels are in
error, the last average
reading is held.
After completing the above steps, IDM returns to the
window. Do one of the following:
To continue programming, refer to Appendix A, Menu Maps, to
navigate to the desired menu.
To leave the User Program, press Exit Page three times.
option is intended for applications where
Totalizer Response
Continues to totalize, based on
the last "good" flow reading.
Stops totalizing.
Stops totalizing.
Stops totalizing.
Stops totalizing during critical
errors.
Totalizer Response
Outputs the average of
Channel1 and Channel2
totals, regardless of the error
state of either channel.
1. If one channel is in error,
totalizing continues.
2. If both channels are in
error, totalizing stops.
November 2004
AVE
Global I/O
1-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents