3.4

Setting Menus

When you press the MENU key during Free Running, the following menu screens appear.
The menu screens are classified by the tab for each setting item.
AMP
DATA
(1) AMP settings
This menu is used to specify input signal-related settings.
Input
Range
Filter
EU
(Scaling
settings)
Annotation string
Misc.
Logic/Pulse
TRIG
USER
<Analog settings>
Setting
[Voltage]
[Temperature]
Function
Meas.
Upper limit
Lower limit
Value
EU output
Upper limit
Lower limit
value
Dec pt
Select
Choose
Arbitrary unit
Inter-CH Op
Function
Operation
Settings
Scaling
Upper/Lower limit
Dec pt
Select
Choose
Arbitrary unit
Span set-
Upper limit
Lower limit
tings
Waveform color setting
Amplitude Setting
Perform Auto Zero ADJ.
Reset Auto Zero ADJ.
[Logic]
Filter
Misc.
Waveform color
setting
[Pulse]
Input
Filter
Slope
EU
Function
Meas. Value
EU output value
Select
Choose
Arbitrary unit
Misc
Waveform color
setting
Amplitude Setting 1 to 8 dots
CHAPTER 3 Settings and Measurement
I/F
OTHER
<Logic Pulse settings>
Selections available
Off, Voltage, Temperature, Humidity
20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 1-5 V
TC-K, TC-J, TC-T, TC-R, TC-E, TC-B, TC-S, TC-N, TC-W, Pt100,
JPt100, Pt1000
Off, 2, 5, 10, 20, 40
Off, On
Set numeric value
Set numeric value
Set numeric value
Set numeric value
EU output upper limit x 1, x 10, x 100, x 1000
Current, length, area, volume, speed, acceleration, frequency, weight,
work, pressure, flow rate, temperature
(The selections vary depending on the unit selected in the above.)
Text input
Text input (Max. 31 characters)
Off, On
CH-X (+, -, x, /) CH-Y
/1000000, /1000, ×1, ×1000, ×1000000
Set numeric value
×1, ×10, ×100, ×1000, ×10000
Current, length, area, volume, speed, acceleration, frequency, weight,
work, pressure, flow rate, temperature
(The selections vary depending on the unit selected in the above.)
Text input
Set numeric value
Set numeric value
0 to 31 for each of red, green, blue (RGB)
1 to 8 dots
Press right key to execute.
Press right key to execute.
Off, Logic, Pulse
Off, On
0 to 31 for each of red, green, blue (RGB)
Off, Revolution counts, Counts, Inst.
Off, On
↑ H, ↓ L
Off, On
Set numeric value
Set numeric value
Current, length, area, volume, speed, acceleration, frequency, weight,
work, pressure, flow rate, temperature
(The selections vary depending on the unit selected in the above.)
Text input
0 to 31 for each of red, green, blue (RGB)
3−17