CHAPTER 4 Specifications

Humidity Sensor B-530 (Option)

Allowable temperature range
Allowable humidity range
Relative humidity measure-
ment accuracy
Method
Relative humidity
measurement accuracy
(5 to 98%)
Response time
Sensor output
External dimensions
Cable length
Sensor power source
Power consumption

List of Options

Logic alarm cable
DC drive cable
Battery pack
Humidity sensor *
midi LOGGER carrying case *2
Extension terminal base set
20 channel extension terminal set
DIN rail jig for GL820 main unit *3
DIN rail jig for GL820 extension
terminal *3
Humidity sensor power box
M3 screws with flat washers (60)
USB memory 2GB
Shunt resistor 250 Ω
T-type thermocouple *2
K-type thermocouple *2
Extra fine K-type thermocouple
(TC200/TD1000), 5 per set
Needle-shape K-type thermo-
couple
Stationery-surface K-type thermo-
couple
L-type stationery-surface K-type
thermocouple
Mini-connector for K-type thermo-
couple (5 per set)
Mini-connector for K-type thermo-
couple (2 per set)
Mini-connector for T-type thermo-
couple (5 per set)
Mini-connector for T-type thermo-
couple (2 per set)
*1: Allowable temperature range: -25 to +80°C
*2: Sold only in Japan.
*3: Can be used also for the GL800 and GL900.
4−8
Item
-25 to +80°C
0 to 100% RH
±3% RH (5 to 98% RH at 25°C)
Capacitance method
Measurement environment
15 s (90% response when membrane filter installed)
0 to 1 VDC
φ14 mm x 80 mm (excluding cable)
3 m
5 to 16 VDC
approx. 4 mA
Item
B-513
B-514
B-517
B-530
1
B-536
B-537
B-538
B-539
B-540
B-542
B-543
B-550
B-551
JSB-7115-5M-T
JSB-7115-5M-K
ST-55K-TC-1.2M Tip wire diameter of
RIC-410
RIC-420
RIC-430
RIC-440
RIC-441
RIC-450
RIC-451
Description
0 to 10°C
10 to 20°C
20 to 30°C
30 to 40°C
40 to 50°C
50 to 60°C
60 to 70°C
70 to 80°C
Model
2 m, Bare tips
2 m, Bare tips
7.4 V/2200 mAh 17 Wh
3 m, with dedicated power connector
Extension terminal base unit, cable
20 channel terminals, extension terminal base unit, con-
nection plate, screws
Built to order
Built to order
For connection with 10 humidity sensors: Built to order
60 per set
2GB
250 Ω, Rated power of 1 W, Maximum service voltage of
15.8 V, Built to order
5-m length, 5 thermocouples per set, wire diameter of
0.32, 1.0 x 1.6 x 5000 mm
5-m length, 5 thermocouples per set, wire diameter of
0.32, 1.0 x 1.6 x 5000 mm
part 1 m, 5 per set
-100 to 300°C, Class 1, Cord length: 1.1 m
-30 to 400°C, Class 2, Cord length: 1.1 m
-30 to 600°C, Class 2, Cord length: 1.1 m
5 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
2 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
5 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
2 per set, Connectable thermocouple: Wire diameter of
0.65 mm, End terminal: M3Y terminal
Measurement accuracy
±5% RH
± 4% RH
± 3% RH
± 4% RH
± 5% RH
± 6% RH
± 7% RH
± 8% RH
Description
φ
0.127, 0.5 x 0.7 x 200 mm, Relay
φ
φ