Sirens & Sounders; Door Locks; Outputs; Chip Key - Abus Secvest User Manual

Table of Contents

Advertisement

Important: ensure that you do not open the housing of a detector. Otherwise the system automatically
exits the walk test and triggers a tampering alarm. Detector housings are only opened by the specialist
installation contractor for maintenance purposes.
Under "Sub-areas" you can select whether only detectors from a certain sub-area are tested. Under "Zones"
you can select whether only certain detectors are tested. The procedure is then the same as for the walk test.
10.7.2 Sirens & sounders
Test the function of different sirens and sounders here. Click on "Change" to test the following:
• Internal sirens:
• External wireless sirens: If at least one wireless siren exists in the system, it can be tested here.
• Sounder Module
• Loudspeaker:

10.7.3 Door locks

If a Secvest key and/or additional door lock is installed, it is a good idea to check its function occasionally.
Engage the lock while the alarm panel is disarmed – the message "Open" or "Closed" is displayed.

10.7.4 Outputs

If a relay output is enabled this menu appears here. Click on "Select" and test the output using the "On/off"
function. If relay contacts (from the Secvest, universal module or wireless socket) have been enabled by the
specialist installation contractor, you can test these if necessary. The corresponding relay contact must be
enabled for you as the user in order to test it. There are relay contacts that only activate when an intruder
alarm is triggered and therefore cannot be accessed in this menu. Speak to your specialist installation
contractor if you wish to access a relay contact, for example to use a wireless socket for lighting control.
10.7.5 Proximity / chip key
If your system has a proximity chip key and you wish to test its function, take the key and swipe it over the
chip key reader area in the lower area of the alarm system (at the height of the ABUS logo). If the chip key is
read successfully, the display indicates which user the chip key is assigned to.
10. User menu
Test the installed sirens of the alarm panel and any indoor sirens here.
We recommend only briefly testing this function. Warn your neighbours
before testing if necessary.
If a universal module (UVM) is installed as a "siren module", you can test
its function here. Again: please warn your neighbours before testing.
Test the installed loudspeaker of the Secvest here. Select "Play/Stop"
to hear all existing messages in the system one after the other.
38
|