Abus Secvest User Manual page 69

Hide thumbs Also See for Secvest:
Table of Contents

Advertisement

Electromagnetic compatibility
EMC – immunity
Electromagnetic compatibility
EMC – interference
Electrical safety
Power supply
Type of power supply
Normal voltage/frequency
Power consumption, maximum
Power consumption, nominal
External DC input fault triggered at
External PSU
Power consumption, typical
15. Technical data
Complies with EN 50130-4
Complies with EN 61000-6-3
Complies with EN60950-1
Type A (EN 50131-1 Section 9 and EN 50131-6 Section 4.1)
Secvest has an integrated power supply unit (Type A). This power supply
unit supplies different internal voltages to the circuit board to supply
power to the circuitry.
This power supply unit supplies 13.8 V with a maximum of 700 mA
at the 0 V/12 V AUX output.
110 V/230 V AC, 50/60 Hz, (85-265 V AC, 50/60 Hz)
13.8 V DC (13.0–14.5 V DC)
I AC MAX:
430mA rms @ 85VAC
190mA rms @ 230VAC
170mA rms @ 265VAC
6.9 W
6.9 W x 24 x 365 = 60 kWh per year
55mA rms @ 230VAC
specified with 200 mA aux load and fully charged batteries
300 mA @ 13.8 V
12.5 V
OK at 12.7 V
13.0–14.5 V DC, at least 1.7 A
Alarm panel standby: 100 mA
Backlighting off
Backlighting:
High: 100 mA
Medium: 40 mA
Low: 15 mA
Internal siren sounding alarm at maximum volume: 70 mA
GSM standby:15 mA
GSM in use: 140 mA
Battery charging current per battery: 220 mA
68 69
68
|

Advertisement

Table of Contents
loading

Table of Contents