Voice dialler
Receiver
DTMF detection VoIP/SIP
Acknowledgement
Codec VoIP/SIP
SMS
Receiver
PSTN SMS protocol
Email
Receiver
Remote control by telephone
ATS Alarm transmission system
Categories and classifications
ATS (Alarm Transmission System)
categories, SPT (Supervised Premises
Transceiver) classification
Classification of transmission time
Transmission time, maximum
values
Classification of notification time
Classification of availability
Security to prevent removal
Information security
15. Technical data
8 Tel or VoIP/SIP ID
RFC 2833
PCM G711 A law (RTP AV Profile 8)
ITU-T G.711 PCM A-Law audio 64 kbit/s
Reference RFC 3551
8
TAP 8N1, TAP 7E1, UCP 8N1, UCP 7E1, ETSI Protocol 1
8
Yes
The alarm panel contains an integrated SP2 (ATS2)
communicator to fulfil the requirements of EN 50131 for security
grade 2.
The alarm transmission system is compliant with
EN 50136-1:2012 as an SP2 (ATS2) communicator.
The alarm panel supports options A, B and C for grade 2 as
given in Table 10 in EN50131-1:2006+A1:2009.
D2 -> SP2
M2 -> SP2
T2 -> SP2
A0 (no requirement)-> SP2 (optional)
There is no method for achieving compliance with EN 50136-
1:2012, 6.7.3 (non-availability of the alarm transmission system)
because A0, no requirement.
S0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with
EN 50136-1:2012, 6.7.2 (redundancy) because S0, no measures.
I0 (no measures) -> SP2 (optional)
There is no method for achieving compliance with
EN 50136-1:2012, 6.8.3 (information security) because I0,
no measures.