Abus Secvest User Manual page 72

Hide thumbs Also See for Secvest:
Table of Contents

Advertisement

RFID proximity keyfob reader
Operating frequency
Special features
Connections
L
N
- DC IN +
13.8 V
0 V 12 V
AUX
+BATT1 ,+BATT2
OP 301, OP 302
OP 303, OP 304
TR
TRB
10/100 LAN
USB TYPE-B
15. Technical data
13.56 MHz
In accordance with:
EN 300 330-2
Individual identification
Mains connection
110 V/230 V AC, 50/60 Hz, (85-265 V AC, 50/60 Hz)
L – line, single phase (black or brown)
– protective earth (yellow/green)
N – neutral (blue)
External PSU input
13.8 V DC, external PSU at least 1.7 A
See Power supply section for more details
Voltage output
13.8 V DC up to 700 mA
Maximum output residual ripple (ripple voltage):
0.2 Vp-p
Aux output fault triggered at 11.5 V, ok from 12.0 V
See Power supply section for more details
Battery polymer lithium ion, 7.4 V, 2500 mAh
Relay output
Potential-free changeover contact NO/C/NC
Max. contact capacity: 500 mA @ 24 V AC rms or 30 V DC
Transistor output
Open-drain
Max. contact capacity: 500 mA @ 13.8 V DC
A negative tamper input
The input is switched to the inactive low state (ground potential)
by the connected siren. The threshold voltages are > 4 V for active
and < 3.6 V for inactive.
A negative fault input
The input is switched to the inactive low state (ground potential)
by the connected siren. The threshold voltages are > 4 V for active
and < 3.6 V for inactive.
Ethernet/LAN
Cat5e patch cable, RJ45 male
Connector at each end, suitable for 10/100Base-T
USB Mini-B connector for alarm panel
USB-A connector for PC
Max. length 3 m