Calibrating Continuous Media

1
Press the PRINT/PAUSE key until the printer is in a paused state.
2
Press the NEXT or PREVIOUS key until the Cal & Setup menu is
displayed, then press the SELECT key.
Pause: Cal & Setup
3
Press the NEXT or PREVIOUS key until the Calibrate menu is displayed.
4
Press the + or - key until Continuous is displayed.
Calibrate
Continuous
5
Press the SELECT key. The printer will feed a short length of media and
will then be calibrated for continuous media. The display will show the
following prompt:
Continuous
Media Calibrated
6
Press the PRINT/PAUSE key to return the printer to a Ready state.

Calibrating Inverted Gap Media

Some examples of inverted gap media include clear labels with an opaque
liner, a material which has sensing marks on the label itself, or a material on
which you must sense on a preprinted image.
When using media of this type, the printer is calibrated using the Gap
Calibration method outlined previously in this chapter.
The only difference in the procedure is that you would align the sensing
mark when the printer prompts for placement of the liner or gap.