Omron E5CN-HT Communications Manual page 65

Digital
Hide thumbs Also See for E5CN-HT:
Table of Contents

Advertisement

Variable
Address
Parameter name
type
C4 (84)
0000
Program Selection
C4 (84)
0001
No. of Segments Used (See note 1.)
C4 (84)
0002
Segment Selection (See note 1.)
C4 (84)
0003
Segment Type (See note 2.)
C4 (84)
0004
Segment SP (See note 2.)
C4 (84)
0005
Segment Slope (See note 2.)
C4 (84)
0006
Segment Time (See note 2.)
C4 (84)
0007
PID Set No. (See note 1.)
C4 (84)
0008
Alarm Value 1
C4 (84)
0009
Alarm Upper Limit 1 (See note 1.)
C4 (84)
000A
Alarm Lower Limit 1 (See note 1.)
C4 (84)
000B
Alarm Value 2 (See note 1.)
C4 (84)
000C
Alarm Upper Limit 2 (See note 1.)
C4 (84)
000D
Alarm Lower Limit 2 (See note 1.)
C4 (84)
000E
Alarm Value 3 (See note 1.)
C4 (84)
000F
Alarm Upper Limit 3 (See note 1.)
C4 (84)
0010
Alarm Lower Limit 3 (See note 1.)
C4 (84)
0011
Program Repetitions (See note 1.)
C4 (84)
0012
Program Link Destination No. (See note
1.)
C4 (84)
0013
Time Signal 1 Set Segment (See note
1.)
C4 (84)
0014
Time Signal 1 ON Time (See note 1.)
C4 (84)
0015
Time Signal 1 OFF Time (See note 1.)
C4 (84)
0016
Time Signal 2 Set Segment (See note
1.)
C4 (84)
0017
Time Signal 2 ON Time (See note 1.)
C4 (84)
0018
Time Signal 2 OFF Time (See note 1.)
Note 1:
The set values for the program specified in the Program Selection parameter are accessed for the following parameters:
No. of Segments Used, Segment Selection, PID Set No., Alarm Values 1 to 3, Alarm Upper Limits 1 to 3, Alarm Lower
Limits 1 to 3, Program Repetitions, Program Link Destination No., Time Signal 1 and 2 Set Segments, Time Signal 1 and 2
ON Times, and Time Signal 1 and 2 OFF Times. Check the set value of the Program Selection parameter before
accessing these parameters.
Note 2:
The set values for the program specified in the Program Selection parameter and the section specified in the Segment
Selection parameter are accessed for the following parameters: Segment Type, Segment SP, Segment Slope, and
Segment Time. Check the set values of the Program Selection parameter and the Segment Selection parameter before
accessing these parameters.
3.1 Variable Area (Setting Range) List
Setting (monitor) value
H'00000000 to H'00000007 (0 to 7)
H'00000001 to H'00000020 (32)
H'00000000 to H'0000001F (31)
H'00000000 (0): Ramp
H'00000001 (1): Soak
H'00000002 (2): Step
SP lower limit to SP upper limit
H'00000000 to H'00007E90 (0 to 32400)
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
H'00000000 to H'00000008 (0 to 8) (0): Automatic Selection
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
'00000000 to '0000270F (0 to 9999)
H'FFFFFFFF(−1): No link
H'00000000 to H'00000007 (0 to 7)
H'00000000 (0) to No. of segments used −1
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
H'00000000 (0) to No. of segments used −1
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
Level
Program
setting
3-15