Omron E5CN-HT Communications Manual page 54

Digital
Hide thumbs Also See for E5CN-HT:
Table of Contents

Advertisement

SECTION 3 Communications Data for CompoWay/F
Variable
Address
Parameter name
type
C1 (81)
0022
MV at Reset
C1 (81)
0023
MV at PV Error
C1 (81)
0024
Manual MV
C1 (81)
0026
MV Upper Limit (See note 1.)
C1 (81)
0027
MV Lower Limit (See note 1.)
C1 (81)
0028
Move to Protect Level
C1 (81)
0029
Password to Move to Protect Level
C1 (81)
002A
Parameter Mask Enable
C1 (81)
002B
PF Key Protect
C1 (81)
002C
MV Change Rate Limit
C1 (81)
002D
Position Proportional Dead Band
C1 (81)
002E
Open/Close Hysteresis
C1 (81)
002F
Heater Overcurrent Detection 1
C1 (81)
0030
Heater Overcurrent Detection 2
C1 (81)
0031
Extraction of Square Root Low-cut
Point
C1 (81)
0032
Program No.
C1 (81)
0033
Fixed SP
C1 (81)
0034
Standby Time
C1 (81)
0035
Program SP Shift Value
C1 (81)
0036
RSP 0 before Correction
C1 (81)
0037
RSP 1 before Correction
C1 (81)
0038
RSP 2 before Correction
C1 (81)
0039
RSP 3 before Correction
C1 (81)
003A
RSP 4 before Correction
C1 (81)
003B
RSP 5 before Correction
C1 (81)
003C
RSP 6 before Correction
C1 (81)
003D
RSP 7 before Correction
C1 (81)
003E
RSP 8 before Correction
C1 (81)
003F
RSP 9 before Correction
C1 (81)
0040
RSP 10 before Correction
3-4
Setting (monitor) value
Standard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A (−105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 (−1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Standard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A (−105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 (−1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Standard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Heating/cooling: H'FFFFFBE6 to H'0000041A (−105.0 to 105.0)
Position proportional (Floating or direct setting of position proportional
MV OFF): H'FFFFFFFF to H'00000001 (−1 to 1)
Position proportional (Closed and direct setting of position proportional
MV ON): H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Standard: MV lower limit + 0.1 to H'0000041A
(MV lower limit + 0.1 to 105.0)
Heating/cooling: H'00000000 to H'0000041A (0.0 to 105.0)
Position proportional (closed): MV lower limit +0.1 to H'0000041A
(MV lower limit +0.1 to 105.0)
Standard: H'FFFFFFCE to MV upper limit −0.1
(−5.0 to MV upper limit −0.1)
Heating/cooling: H'FFFFFBE6 to H'00000000 (−105.0 to 0.0)
Position proportional (closed): H'FFFFFFCE to MV upper limit −0.1
(−5.0 to MV upper limit −0.1)
H'FFFFF831 to H'0000270F (−1999 to 9999)
H'FFFFF831 to H'0000270F (−1999 to 9999)
(Can only be set. The monitor value is always H'00000000.)
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000001 to H'00000064 (0.1 to 10.0)
H'00000001 to H'000000C8 (0.1 to 20.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'000001F4 (0.0 to 50.0)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000000 to Hí00000007 (0 to 7)
SP lower limit to SP upper limit
H'00000000 to H'00009959 (hours, minutes)
H'00000000 to H'00009923 (days, hours)
H'FFFFB1E1 to H'00007E90 (−19999 to 32400)
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Remote SP lower limit to remote SP upper limit
Level
Adjustment
Manual
Control
Adjustment
Protect
Adjustment
Operation
Adjustment

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5en-htE5an-ht

Table of Contents