SECTION 3 Communications Data for CompoWay/F
Variable
Address
Parameter name
type
C3 (83)
0073
PV/SP Display Screen Selection
C3 (83)
0074
MV Display Selection
C3 (83)
0075
PV Decimal Point Display
C3 (83)
0076
PV Status Display Function
C3 (83)
0077
SV Status Display Function
C3 (83)
0078
Control Output 1 ON/OFF Count Alarm
Set Value
C3 (83)
0079
Control Output 2 ON/OFF Count Alarm
Set Value
C3 (83)
0083
Display Refresh Period
C3 (83)
0084
Program Time Unit
C3 (83)
0085
Time Setting/Gradient Setting
C3 (83)
0086
Gradient Time Setting Unit
C3 (83)
0087
Reset Operation
C3 (83)
0088
Startup Operation
C3 (83)
0089
Operation End Operation
C3 (83)
008A
PV Start
C3 (83)
008B
Program End ON Time
C3 (83)
008C
Standby Time Unit
C3 (83)
008D
Program SP Shift Value Addition
C3 (83)
008E
RSP Broken-line Correction Display
Addition
Note 1:
Selection is not possible when ON/OFF control is set.
Note 2:
Selection is not possible if the Reset Operation parameter is set to fixed SP operation.
3-14
Setting (monitor) value
H'00000000 (0): Only PV/SP displayed (no No. 3 display).
H'00000001 (1): The PV/SP/Program No. or Segment No., and the
PV/SP/MV are displayed in order.
H'00000002 (2): The PV/SP/MV and PV/SP/Program No. or Segment
No. are displayed in order.
H'00000003 (3): Only the PV/SP/Program No. or Segment No. are
displayed.
H'00000004 (4): Only the PV/SP/MV are displayed.
H'00000005 (5): The PV/SP/Program No. or Segment No., and the
PV/SP/Remaining Segment Time are displayed in
order.
H'00000006 (6): The PV/SP/MV and PV/SP/Remaining Segment
Time are displayed in order.
H'00000007 (7): Only the PV/SP/Remaining Segment Time are dis-
played.
H'00000000 (0): MV (heating)
H'00000001 (1): MV (cooling)
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 (0): OFF
H'00000001 (1): Manual
H'00000002 (2): Reset
H'00000003 (3): Alarm 1
H'00000004 (4): Alarm 2
H'00000005 (5): Alarm 3
H'00000006 (6): Alarm 1 to 3 OR status
H'00000007 (7): Heater alarm
H'00000008 (8): Standby
H'00000000 to H'00000008 (0 to 8)
* Same as for PV Status Display Function
H'00000000 to H'0000270F (0 to 9999)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 (0): OFF
H'00000001 (1): 0.25
H'00000002 (2): 0.5
H'00000003 (3): 1.0
H'00000000 (0): Hours, minutes
H'00000001 (1): Minutes, seconds
H'00000000 (0): Time setting
H'00000001 (1): Gradient setting
H'00000000 (0): Minutes
H'00000001 (1): Hours
H'00000000 (0): Stop control
H'00000001 (1): Fixed SP operation
H'00000000 (0): Continue control at final SP
H'00000001 (1): Reset
H'00000002 (2): Run
H'00000003 (3): Manual (See note 1.)
H'00000000 (0): Reset
H'00000001 (1): Continue control at final SP
H'00000002 (2): Fixed SP mode (See note 2.)
H'00000000 (0): SP-priority SP start
H'00000001 (1): Slope-priority PV start
H'00000000 to H'00000064 (0.0 to 10.0)
H'FFFFFFFF(ON)
H'00000000 (0): Hours, minutes
H'00000001 (1): Days, hours
H'00000000 (0): OFF
H'00000001 (1): ON
H'00000000 (0): OFF
H'00000001 (1): ON
Level
Advanced
function
setting
Advanced
function
setting
Initial
setting
Advanced
function
setting