Protection Requirements For A Mast Or Tower Installation; Figure 2-2 Grounding Cable Minimum Bend Radius And Angle - Motorola PTP 250 User Manual

Hide thumbs Also See for Motorola PTP 250:
Table of Contents

Advertisement

Grounding and lightning protection

Figure 2-2 Grounding cable minimum bend radius and angle

Radius not less
than 203 mm (8 in)
ODU requirements
The following ODU protection requirements must be implemented:
The ODU must be grounded to the supporting structure.

Protection requirements for a mast or tower installation

If the ODU is to be mounted on a metal tower or mast, then in addition to the general
protection requirements (above), the following requirements must be observed:
The equipment must be lower than the top of the tower or its lightning air terminal.
The metal tower or mast must be correctly grounded.
A grounding kit must be installed at the first point of contact between the drop cable
and the tower, near the top.
A grounding kit must be installed at the bottom of the tower, near the vertical to
horizontal transition point. This grounding kit must be bonded to the tower or tower
ground bus bar (TGB), if installed.
If the tower is greater than 61 m (200 ft
installed at the tower midpoint. Additional ground kits must be installed as necessary
to reduce the distance between ground kits to 61 m (200 ft) or less.
In high lightning prone geographical areas, additional ground kits should be installed
at spacing between 15 to 22 m (50 to 75 ft
taller than 45 m (150 ft).
A schematic example of a mast or tower installation is shown in
2-18
UNDER DEVELOPMENT
Chapter 2: Planning considerations
in height, an additional grounding kit must be
)
. This is especially important on towers
)
phn-2182_003v004 (Oct 2011)
Angle not less
than 90°
Figure
2-3.