Maximum Cable Lengths; Wind Loading; Table 2-3 Maximum Cable Lengths - Motorola PTP 250 User Manual

Hide thumbs Also See for Motorola PTP 250:
Table of Contents

Advertisement

PTP 250 User Guide

Maximum cable lengths

The maximum permitted lengths of interface cables in PTP 250 installations are specified
in
Table
2-3.

Table 2-3 Maximum cable lengths

Interface type
Ethernet power
and data

Wind loading

Ensure that the supporting structure will not be prone to excessive wind loading.
Antennas and equipment mounted on towers or buildings will subject the mounting
structure to significant lateral forces when there is appreciable wind. Antennas are
normally specified by the amount of force (in pounds) for specific wind strengths. The
magnitude of the force depends on both the wind strength and size of the antenna.
The ODU, with or without the integral antenna, is essentially a flat structure. The
magnitude of the lateral force can be estimated from surface area and wind speed.
Calculation of lateral force (metric)
The magnitude of the lateral force can be estimated from:
Force (in kilograms) = 0.1045aV
phn-2182_003v004 (Oct 2011)
Interface
ODU to network terminating equipment.
2
Where:
a
V
UNDER DEVELOPMENT
Is:
surface area in square meters
wind speed in meters per second
Site planning
Maximum
length
100 m (330 ft)
2-7

Advertisement

Table of Contents
loading

Table of Contents