PTP 250 User Guide
Check that the ODU is pre-fitted with a mounting bracket (designed to ease installation)
and with a ground cable
Figure 5-1 Checking the ODU before mounting
Do not mount the ODU on poles with diameter less than 50mm (2") or greater than 75mm
(3"). The ODU mounting bracket is designed to work only with poles with diameter in the
50 mm (2") to 75 mm (3") range.
Before hoisting the ODU, take the following precautions:
•
Check that the safety loop
have not been exposed to a shock loading due to a fall.
•
Check that the safety lanyard does not exceed 1m (approx 3 ft) in length.
•
Check that the safety lanyard is made from a material that does not degrade in an
outdoor environment.
•
Check that the safety lanyard is fixed to a separate point that is not part of the direct
mounting system for the ODU.
phn-2182_003v004 (Oct 2011)
(Figure
5-1).
(Figure
5-1) and its fixing are not damaged in any way and
UNDER DEVELOPMENT
Installing the ODU
5-5