Restoring, resetting and rebooting
Recovering a lost IP address
To recover a lost IP address, physical access to the PoE power supply is recommended.
The unit does still respond to its normal IP address through a power cycle.
If the IP address of the unit has been lost or forgotten, proceed as follows:
1
Set the management PC Ethernet port to an IP address that is valid for the
169.254.X.X network, avoiding 169.254.0.0, 169.254.1.1 and 169.254.1.2. Refer
to
Configuring the management PC
2
Connect the management PC Ethernet port to the DATA IN port of the PoE
power supply using a standard (not crossed) Cat5e cable
3
Perform a power cycle, that is, disconnect and then reconnect the PoE power
supply to its AC supply.
4
Access the web interface within 30 seconds of powering on, using default IP
address 169.254.1.1.
5
Select menu option Configuration, LAN Configuration.
6
Obtain the correct IP address of the unit from the LAN Configuration page.
Rebooting the unit
To reboot the ODU select menu option Reboot PTP 250. The Reboot Wireless Unit page is
displayed
(Figure
Figure 7-14 Reboot Wireless Unit page
7-28
7-14). Select Reboot PTP 250 to confirm.
UNDER DEVELOPMENT
on page 6-3.
phn-2182_003v004 (Oct 2011)
Chapter 7: Operation
(Figure
6-3).