Making A Drop Cable Ground Point - Motorola PTP 250 User Manual

Hide thumbs Also See for Motorola PTP 250:
Table of Contents

Advertisement

PTP 250 User Guide

Making a drop cable ground point

Perform this task to connect the screen of the drop cable to the metal of the supporting
structure using a cable grounding kit.
The cable grounding kit for 1/4" and 3/8" cable
components:
1 x grounding cable with grounding 2 hole lug fitted (M10)
1 x self Amalgamating tape
1 x PVC tape
3 x tie wraps
2 x bolt, washer and nut
Ground cables must be installed without drip loops and pointing down towards the ground;
otherwise they may not be effective.
To ground the drop cable to a metal structure using the Motorola grounding kit (part
number 01010419001), proceed as follows:
1
Remove 60 mm (2.5 inches) of the drop cable outer sheath.
2
Cut 38mm (1.5 inches) of rubber tape (self amalgamating) and fit to the ground
cable lug. Wrap the tape completely around the lug and cable.
phn-2182_003v004 (Oct 2011)
(Figure
1-8) contains the following
UNDER DEVELOPMENT
Installing the drop cable and LPU