Pidu Plus - Ptp 600 Series Bridge; Figure 4 - Power Indoor Unit (Pidu Plus) - Ptp 300/500/600 Series; Figure 5 - Pidu Plus Recovery Switch Location - Motorola PTP 600 Series User Manual

Point-to-point wireless solutions
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

3 Getting Started
3.3.2
PIDU Plus – PTP 600 Series Bridge
The PTP 600 Series Bridge PIDU Plus is used to generate the ODU supply voltage from the
mains supply and inject this supply voltage into the 1000BaseT Ethernet connection to the
ODU. Connection uses a CAT5e cable using standard RJ45 wiring.
CAUTION: Care should be taken not to connect equipment other than an ODU for the PTP
600 Series Bridge to a PIDU Plus ODU port as equipment damage may occur. The PTP 600
Series Bridge PIDU Plus is not interchangeable with the PTP 400 Series PIDU Plus.
Figure 4 - Power Indoor Unit (PIDU Plus) – PTP 300/500/600 Series
The front panel contains indicators showing the status of the power and Ethernet
connections.
The power indicator is illuminated when the PIDU Plus is receiving mains power.
The Ethernet indicator normally illuminates when the Ethernet link is working, flashing when
there is Ethernet activity. The fact that it lights also indicates that the ODU is powered. At
power up the LED will flash 10 times to indicate that a correct start up sequence has
occurred. See Section 11 "Fault Finding" for further fault finding information.
At the bottom of the PIDU Plus is an entry point for the PIDU Plus to ODU cable, the
1000BaseT Ethernet network port and the Recovery switch.
Figure 5 – PIDU Plus Recovery Switch Location
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents