Diagnostic Plotter; Figure 95 - Diagnostic Plotter - Motorola PTP 600 Series User Manual

Point-to-point wireless solutions
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

8.3.12.1 Diagnostic Plotter

New for the PTP 600 Series is the system administration diagnostic plotter facility see Figure
95.
The diagnostic plotter allows the system administrator to view the cascading histogram data
in an easily accessible graphical form. The plot always displays three traces, maximum,
minimum and mean by default. The diagnostic selector allows the user to select the various
categories of histogram.
The histograms that are available are:
x
Vector Error
x
Rx Power
x
Tx Power
x
Signal Strength Ratio
x
Link Loss
x
Rx Data Rate
x
Tx Data Rate
x
Aggregate Data Rate
The diagnostic plotter uses a novel time representation in the x-axis which compresses the
timeline of the plot without sacrificing resolution.