Mounting The Odus; Figure 36 - Mounting To Pole Diameters 25Mm (1") To 50Mm (2") - Motorola PTP 600 Series User Manual

Point-to-point wireless solutions
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

7.6
Mounting the ODU
The ODU mounting bracket is designed to ease installation by fixing the bracket to a pole and
then bringing the ODU into position using a single bolt fixing. The ODU should be mounted
using the following steps ensuring that the cable entry is at the bottom.
The ODU mounting bracket is designed to work with poles with diameters in the range 50mm
(2") to 75mm (3").

Figure 36 - Mounting to pole diameters 25mm (1") to 50mm (2")

Step 1: Mount the bracket to the pole.
Pole diameters of 25mm (1") to 50mm (2") can be accommodated by inverting the back of the
bracket as shown in Figure 36.
When adjustment is complete tighten all bolts to 14Nm (11lb ft).
CAUTION: Do not over tighten the bolts as bracket failure may occur.
The enclosure and mounting brackets of the PTP 600 Series Bridge product range are
capable of withstanding wind speeds up to 151mph (242kph). The installer should ensure that
the structure the bridge is fixed to is also capable of withstanding the prevalent wind speeds
and loads. See Section 12 "Wind Loading".
s
101
Step 2: Mate the unit to the bracket together
and tighten the nut and bolt.