HEATER ENGINE - GENERAL INSTALLATION

ELECTRICAL SUPPLY

Where a power point is used it MUST BE 230 V or 240 V, rated at 10A and MUST
BE earthed. This power point MUST NOT be located above the heater.
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
exits the appliance from the rear panel at the lower left.
Direct Wired Installations
Alternatively the appliance can be direct wired if so required.
A qualified electrician will need to be consulted where a direct
wired installation is required. Any such installation must comply
IMPORTANT
with the requirements of AS/NZS 5601, AS/NZS 3000 and any
other relevant local regulations.

FLUEING

The following diagrams illustrate the flue installation options that are available for the RDV600ER
and RDV700ER space heaters. Only the genuine Rinnai flue is certified as part of the space
WARNING
heaters installation requirements.
Only an authorised person must install, service and remove the Rinnai RDV600ER and RDV700ER
space heaters space heater & flue system.
Only the flue system components described in this Manual are suitable and MUST BE used.
Components that are not described in that manual, whether manufactured by Rinnai or otherwise,
are NOT compatible and MUST NOT be used.
Rinnai appliance warranty conditions may be voided if non Rinnai flue components are fitted.
AS/NZS 5601 "GAS INSTALLATIONS" requires that flue components be supported independently
of the appliance.
Flue Installation Options
Masonry
i
A
C
B
H
ii
D
D
E
i. Vertical
ii. Horizontal
Masonry (Co-linear) cowl
A
Co-linear to coaxial adaptor & support plate/mount
B
Flexi pipes (100Ø exhaust / 75Ø intake)
C
Spigot plate (this is part of the heater engine)
D
Heater engine
E
Rinnai
False Fire Place
i
ii
A
F
C
B
D
E
ii. Vertical Offset
iii. Horizontal
7a
which
G
iii
H
F
B
F
C
D
E
i. Vertical
Coaxial pipe components (170Ø outer pipe, a max
F
of 2 x 45º bends ONLY are allowed)
Vertical cowl
G
Horizontal terminal
H
Weather proof box.
I
25
Weather Proof Box
B
H
C
D
E
I
Reduces the internal
footprint requirements
of the heater engine
RDV 600_700 OIM
7a
C