Enclosure Dimensions - Rinnai 650 Operation & Installation Manual

Hide thumbs Also See for 650:
Table of Contents

Advertisement

False Fireplace Installation
Framework of the installation must conform to local building codes. Non-combustible materials need not be used.
If the appliance is elevated from the ground within the structure, a base must be constructed using suitable material
with supporting joists capable of supporting a minimum of 1.5 times the weight of the appliance.
AS/NZS 5601 "GAS INSTALLATIONS" requires that flue components be supported independently
of the appliance.
CAUTION

ENCLOSURE DIMENSIONS

Enclosure dimensions are shown below. The enclosure dimensions specified are critical to the successful
installation of this appliance and must be strictly adhered to.
MASONRY INSTALLATION
W1
H1
D
Enclosure Type (All dimensions are minimums and are in mm unless otherwise stated)
Height
Model
(H1)
RDV600ER
600
RDV700ER
600
§ Framing MUST include supports for the mounting of the co-linear to coaxial flue adaptor.
The co-linear flexible flue MUST NOT come into contact with ANY combustible material.
WARNING
# The enclosure dimension for False Fireplace installations are larger, to make allowances for the
fitment of the zero clearance frame. The fitment of this frame is necessary to provide the required
clearances from any combustibles.
For clarity the consumer piping gas supply, electrical connections have been omitted, refer to
page 24 and page 25 for details. Construction details have also been simplified.
CAUTION
* As the heater engine is installed flush with the external surface, when preparing the cavity the
minimum depth needs to be inclusive of the external cladding thickness for false fireplace
installations. It is the installers responsibility that adequate clearance be provided between the
heater engine and any electrical connections on the inside of a masonry fireplace.
‡ Corner installations use False Fireplace enclosure dimensions and framing specifications.
In a masonry fireplace, use a slurry of sand and cement to level the base as required.
NOTE
Rinnai
HEATER LOCATION
FALSE FIREPLACE INSTALLATION
Masonry
Width
Depth
Chimney
(W1)
(D)
(X)
600
400 *
200 x 200
700
400 *
200 x 200
Y
W2
H2
D
False Fireplace
Height
Width
Depth
(H2)
(W2)
(D)
700 # 700 #
400 *
700 # 800 #
400 *
23
CORNER INSTALLATION
Corner ‡
Support
Face
Sides
(Y)
(A)
(B)
Max 600 §
1400
976
Max 600 §
1500
1047
RDV 600_700 OIM
Depth
(C)
676
726