4. FC 300 Selection
Line Supply 3 x 200-240 VAC
FC 301/FC 302
High/ Normal Load*
Output current
4
Max. input current
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
62
HO
Typical
Shaft
Output
5.5
[kW]
Enclosure IP 21
Enclosure IP 55, 66
Continuous
24.2
(3 x 200-240 V) [A]
Intermittent
(60 sec overload)
38.7
(3 x 200-240 V) [A]
Continuous
8.7
KVA (208 V AC) [KVA]
Continuous
22
(3 x 200-240 V) [A]
Intermittent
(60 sec overload)
35.2
(3 x 200-240 V) [A]
Max. cable size [mm
2
(AWG)]
2)
Max. pre-fuses [A]
1
Estimated power loss
239
4)
at rated max. load [W]
Weight,
enclosure IP 21, IP 55,
66 [kg]
Efficiency
4)
MG.33.B9.22 - VLT
®
is a registered Danfoss trademark.
P5K5
P7K5
NO
HO
NO
7.5
7.5
11
B1
B1
B1
B1
30.8
30.8
46.2
33.9
49.3
50.8
11.1
11.1
16.6
28
28
42
30.8
44.8
46.2
16 (6)
16 (6)
63
63
310
371
514
23
23
0.964
0.959