4.3 Start-Up Flowcharts
u

Subchart A-2: High Performance Operation Using OLV or CLV

Flowchart A2 in
Figure 4.6
Loop Vector Control, which is appropriate for applications requiring high starting torque and torque limits.
Note: Although the drive sets parameters for the PG encoder during Auto-Tuning, sometimes the direction of the motor and direction of the PG get
reversed. Use parameter F1-05 to switch the direction of the PG so that it matches the motor direction.
<1> Decouple the load from the motor to properly perform Rotational Auto-Tuning.
<2> Rotational Auto-Tuning can still be performed if the load is 30% or less, though Stationary Auto-Tuning may yield better control
performance.
<3> Make sure the motor and load can run freely (i.e., if a brake is mounted, make sure it is released).
<4> ASR Gain Tuning automatically performs Inertia Tuning and sets parameters related to Feed Forward and the KEB Ride-Thru
function.
84
describes the setup procedure for high-performance with Open Loop Vector Control or Closed
From
Flowchart
A
Possible for motor to
rotate during tuning?
<1>
NO
NO
Motor test report/
data sheet available?
NO
Perform Stationary
Auto-Tuning 1 (T1-01 = 1)
Run the motor without load; check the rotation direction and operation.
Verify external signal commands to the drive work as desired.
Connect the load to the motor.
Is there a PG
encoder on the
motor?
YES
Should the
drive set ASR gain
automatically?
NO
Does the application require
any of the following drive functions?
 Feed Forward
 KEB 2
NO
Run the machine and check for desired
operation.
Return to
Flowchart
A
Figure 4.6 Flowchart A2: High Performance Operation Using OLV or CLV
YES
Is the load less than
30% of the rated load
for the motor?
YES
Perform Stationary
Auto-Tuning 2 (T1-01 = 4)
NO
YES
YES
Perform Inertia Tuning
(T1-01 = 8)
<3>
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
YES
<2>
Perform Rotating
Auto-Tuning (T1-01 = 0)
Perform ASR gain tuning.
(T1-01 = 9)
<4>