Galaxy 3 Series Programming Manual
Pressing the
and # keys again toggles the display to show the status of the groups individually. To move
between each groups, press the
Pressing the
and # keys again returns the keypad to the banner display.
Galaxy 3-520
The Galaxy 520 panel has 32 groups; these are displayed on the keypad in blocks of eight groups, sub-
divided into A, B, C and D:

Exit Time

Once the setting routine starts, outputs programmed as Entry/Exit Horn emit a continuous tone. The keypad
used to set the system indicates the time, in seconds, remaining before the system sets.

Exit Time Reset

If any zones are open when setting starts or are opened during the setting routine, the sounder begins to pulse
rapidly; zones types other than Final, Exit, Entry or Push-Set (and Secure Final or Part Final when acting
as a Final), indicate on the setting keypad the number of zones open. The A or B keys can be used to view
the open zone types and addresses. Closing the zones resets and restarts the exit time.

Omitted Zones

If zones are omitted when the system starts setting, this is indicated on the keypad. The keypad indicates how
many zones are omitted.

Expiry Warning

During the last 25% of the programmed exit time outputs programmed as Entry/Exit Horn begin to pulse
rapidly, indicating that time is running short.

System Set Indication

At the end of the exit time the Entry/Exit Horns become silent for four seconds. This allows the door to be
locked and secured and gives the detectors time to settle before the system finally sets. Two long tones are
emitted to confirm that the system has set. If all groups are set the keypad briefly displays the message SYS-
TEM IS SET before returning to the normal banner.

Group Logic Setting Restriction

If Setting Logic has been assigned to a group (refer to 63.1.2 = OPTIONS.Groups.Setting Logic), the set
status of the groups must satisfy the conditions defined in the option to permit the group to set. If the Setting
Logic conditions are not satisfied, then the group cannot set. If multiple groups are being set simultaneously,
but one group is restricted due to the programmed Setting Logic, the remainder of the groups set. The
restricted group does not set; there is no warning or indication given.
and A or the
and B keys simultaneously.
08:58 TUE 22 NOV
08:58 TUE 22 NOV
08:58 TUE 22 NOV
08:58 TUE 22 NOV
08:58 TUE 22 NOV
A1U Group A1
A1U Group A1
A1U Group A1
A1U Group A1
A1U Group A1
Group A1 is unset
11
Setting Features (cont'd)