LYNX Touch Installation and Setup Guide
System Operation

Event Log

The LYNX Touch Series event log is capable of recording and displaying up to 128 system events. The type
of events that can be recorded is selectable and is programmed in the System Type programming field. The
event log can be reviewed by entering the Installer Programming or Master User Programming mode. Refer
to the LYNX Touch Series User Manual for additional information.
Note: In the unlikely condition that the backup battery becomes fully discharged when AC power is lost, any system activity performed after
the low battery notification will not be saved in the event log. Additionally, the panel will revert to the status condition as before the low
battery notification.
CID
Code
110
Alarm, Fire
121
Alarm, Duress
122
Alarm, Silent
123
Alarm, Audible
131
Alarm, Perimeter
132
Alarm, Interior
134
Alarm, Entry/Exit
135
Alarm, Day/Night
137
Alarm, Tamper
145
Expansion Module Tamper
146
Silent Burglary
150
24-Hour Non-Burglary
162
Carbon Monoxide Detected
301
Trouble, AC Loss
302
Trouble, Low System Battery
305
Trouble, System Reset
316
System Tamper*
341
Trouble, Case Tamper
344
Trouble, RF Receiver Jam Detect
351
Trouble, Telco 1 Fault
353
Trouble, Long Range Radio Transmitter Fault
373
Trouble, Fire Trouble
374
Trouble, Exit Error Alarm
380
Trouble, Sensor
381
Trouble, Loss of Supervision RF
383
Trouble, Sensor Tamper
384
RF Low Battery
401
Open/Close by User
403
Open/Close Automatic
406
Cancel
407
Remote Arm/Disarm
408
Quick Arm
441
Armed Stay
455
Auto-Arm Failed
459
Recent Close
570
Zone/Sensor Bypass
601
Manual Trigger Test Report
602
Periodic Test Report
606
Listen-in to follow
607
Walk Test
623
Event 90% Full
627
Program Mode Entry (Logged in Event Log Only)
628
Program Mode Exit (Logged in Event Log Only)
654
System Inactivity
655
Reset Master Code (Logged in Event Log Only)
759
Resident Monitor Zone Response
760
Resident Response Zone Response
761
General Monitor Zone Response
762
General Response Zone Response
Contact ID ® & SIA Event Log Codes
Definition
SIA
Code
AT/AR
AC Trouble/AC Restoral
BA/BR
Burglary Alarm/Burglary Restoral
CA/CD
Automatic Closing/Closing Delinquent
CI
Fail to Close (Log only)
CL
Closing Report
CQ
Remote Closing
CR
Recent Closing
DF/DR
Door Forced/Door Restoral
EA
Exit Alarm
ES/EJ
Expansion Device Tamper/Expansion Tamper Restore
ET
Expansion Trouble
FA
Fire Alarm
FT/FJ
Fire Trouble/Fire Trouble Restore
HA/HR
Holdup Alarm/Holdup Restoral
GA/GR
Gas Alarm/Gas Restoral
FT/FJ
Fire Trouble/Fire Trouble Restore
LT/LR
Phone Line Trouble/Phone Line Restoral
OA
Automatic Opening
OC
Cancel Report
OP
Opening Report
OQ
Remote Opening
PA
Panic Alarm
RP
Automatic Test
RX
Manual Test
TA/TH
Tamper Alarm/Tamper Alarm Restore
TJ
Tamper Trouble Restore
TS/TE
Test Start/Test End
TT
Tamper Trouble
UA
Untyped Zone Alarm
UB/UU
Untyped Zone Bypass/Untyped Zone Unbypass
UT/UJ
Untyped Zone Trouble/Restore
XG/XH
RF Interference/RF Interference Restore
XT/XR
Transmitter Battery Trouble/Transmitter Battery Restoral
YT/YR
System Battery Trouble/System Battery Restoral
*If APL is enabled, AlarmNet will generate a special comm. fail
message (E316) if it does not hear from a unit within 15 minutes
after a delayed alarm is delivered. This message is meant to alert
the Central Station that the system has been tampered with and
may have been compromised.