timer quiet (HWTACACS scheme view)

Use timer quiet to set the quiet timer for the servers specified in an HWTACACS scheme.
Use undo timer quiet to restore the default.
Syntax
timer quiet minutes
undo timer quiet
Default
The server quiet period is 5 minutes.
Views
HWTACACS scheme view
Predefined user roles
network-admin
Parameters
minutes: Server quiet period in minutes, in the range of 1 to 255.
Examples
# Set the server quiet timer to 10 minutes.
<Sysname> system-view
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] timer quiet 10
Related commands
display hwtacacs scheme

timer realtime-accounting (HWTACACS scheme view)

Use timer realtime-accounting to set the real-time accounting interval.
Use undo timer realtime-accounting to restore the default.
Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
Default
The real-time accounting interval is 12 minutes.