Legacy Zone Alias Configuration; Importing A Zone Alias; Device Alias Database Merge Guidelines - Cisco Nexus 5000 Series Configuration Manual

Nx-os san
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Legacy Zone Alias Configuration

Operation: Disable Fabric Distribution
Status: Success
Legacy Zone Alias Configuration
You can import legacy zone alias configurations to use this feature without losing data if they satisfy the
following restrictions:
• Each zone alias has only one member.
• The member type is pWWN.
If any name or definition conflict exists, the zone aliases are not imported.
Ensure that you copy any required zone aliases to the device alias database as required by your configuration.
When an import operation is complete, the modified alias database is distributed to all other switches in the
physical fabric when you perform the commit operation. If you do not want to distribute the configuration to
other switches in the fabric, you can perform the abort operation and the merge changes are completely
discarded.

Importing a Zone Alias

You can import the zone alias for a specific VSAN.
SUMMARY STEPS
1. configure terminal
2. device-alias import fcalias vsan vlan-id
DETAILED STEPS
Command or Action
Step 1
configure terminal
Example:
switch# configure terminal
switch(config)#
Step 2
device-alias import fcalias vsan vlan-id
Example:
switch(config)# device-alias import fcalias vsan

Device Alias Database Merge Guidelines

When merging two device alias databases, follow these guidelines:
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
176
Distributing Device Alias Services
Purpose
Enters global configuration mode.
Imports the fcalias information for the specified
VSAN.
OL-27583-01

Advertisement

Table of Contents
loading

Table of Contents