Cisco Nexus 5000 Series Nx-Os San Switching Configuration Guide, Release 5.2(1)N1(1 - Cisco Nexus 5000 Series Configuration Manual

Nx-os san
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Information About Fibre Channel Interfaces
Reason Code (long version)
SFP not present
Initializing
Reconfigure fabric in progress
Offline
Inactive
Hardware failure
Error disabled
Isolation because limit of active
port channels is exceeded.
Isolation due to ELP failure
Isolation due to ESC failure
Isolation due to domain overlap

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)

14
Description
The small form-factor pluggable
(SFP) hardware is not plugged in.
The physical layer link is
operational and the protocol
initialization is in progress.
The fabric is currently being
reconfigured.
The switch software waits for the
specified R_A_TOV time before
retrying initialization.
The interface VSAN is deleted or
is in a suspended state.
To make the interface operational,
assign that port to a configured and
active VSAN.
A hardware failure is detected.
Error conditions require
administrative attention. Interfaces
may be error-disabled for various
reasons. For example:
• Configuration failure.
• Incompatible buffer-to-buffer
credit configuration.
To make the interface operational,
you must first fix the error
conditions causing this state and
then administratively shut down or
enable the interface.
The interface is isolated because
the switch is already configured
with the maximum number of
active SAN port channels.
The port negotiation failed.
The port negotiation failed.
The Fibre Channel domains
(fcdomain) overlap.
Configuring Fibre Channel Interfaces
Applicable Modes
All
All
Only E ports and TE ports
OL-27583-01

Advertisement

Table of Contents
loading

Table of Contents