Advanced Fibre Channel Features
Example:
switch# show fcdomain vsan 1
The local switch is a Subordinated Switch.
Local switch run time information:
State: Stable
Local switch WWN:
Running fabric name: 10:00:00:60:69:22:32:91
Running priority: 128
Current domain ID: 0x64(100) <---------------verify domain id
Local switch configuration information:
State: Enabled
Auto-reconfiguration: Disabled
Contiguous-allocation: Disabled
Configured fabric name: 41:6e:64:69:61:6d:6f:21
Configured priority: 128
Configured domain ID: 0x64(100) (preferred)
Principal switch run time information:
Running priority: 2
Interface
----------------
fc2/1
fc2/2
fc2/4
----------------
Step 6
Verify the local principal switch status.
Example:
switch# show fcdomain domain-list vsan 1
Number of domains: 5
Domain ID
---------
0x61(97)
0x62(98)
0x63(99)
0x64(100)
OL-27583-01
20:01:00:05:30:00:51:1f
Role
-------------
Downstream
Downstream
Upstream
-------------
WWN
-----------------------
10:00:00:60:69:50:0c:fe
20:01:00:05:30:00:47:9f
10:00:00:60:69:c0:0c:1d
20:01:00:05:30:00:51:1f [Local]