Configuring Port Tracking
Command or Action
Step 3
no port-track enable
Example:
switch(config)# no port-track enable

Configuring Linked Ports

You can link ports using one of two methods:
• Operationally binding the linked ports to the tracked port (default).
• Continuing to keep the linked port down forcefully, even if the tracked port has recovered from the link

Operationally Binding a Tracked Port

When you configure the first tracked port, operational binding is automatically in effect. When you use this
method, you have the option to monitor multiple ports or monitor ports in one VSAN.
To operationally bind a tracked port, perform this task:
SUMMARY STEPS
1. switch# configure terminal
2. switch(config)# interface fc slot/port
3. switch(config-if)# port-track interface fc slot/port | san-port-channel port
4. switch(config-if)# no port-track interface fc slot/port | san-port-channel port
DETAILED STEPS
Command or Action
Step 1
switch# configure terminal
Step 2
switch(config)# interface fc slot/port
Step 3
switch(config-if)# port-track interface fc slot/port
| san-port-channel port
Step 4
switch(config-if)# no port-track interface fc
slot/port | san-port-channel port
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
290
failure.
Purpose
Removes the currently applied port tracking
configuration and disables port tracking.
Purpose
Enters global configuration mode.
Enters the interface configuration mode for the linked port.
You can now configure the tracked ports.
Specifies the tracked port. When the tracked port goes down,
the linked port is also brought down.
Removes the port tracking configuration that is currently
applied to the interface.