Cisco Nexus 5000 Series Configuration Manual page 256

Nx-os san
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Switch Interoperability
no shutdown
interface fc2/2
no shutdown
interface fc2/3
interface fc2/4
<snip>
interface mgmt0
ip address 6.1.1.96 255.255.255.0
switchport encap default
no shutdown
vsan database
vsan 1 interop
boot system bootflash:/nx5000-system-23e.bin
boot kickstart bootflash:/nx5000-kickstart-23e.bin
callhome
fcdomain domain 100 preferred vsan 1
ip route 6.1.1.0 255.255.255.0 6.1.1.1
ip routing
line console
databits 5
speed 110
logging linecard
ssh key rsa 512 force
ssh server enable
switchname switch
username admin password 5 $1$Li8/fBYX$SNc72.xt4nTXpSnR9OUFB/ role network-admin
Step 4
Verify if the interoperability mode is active.
Example:
switch# show vsan 1
vsan 1 information
name:VSAN0001
interoperability mode:yes <-------------------- verify mode
loadbalancing:src-id/dst-id/oxid
operational state:up
Step 5
Verify the domain ID.
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
234
state:active
Advanced Fibre Channel Features
OL-27583-01