Ricoh MP C2504 Field Service Manual page 1906

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

1-013-002 -
1014
[Scan to Folder Pass Input Set]
1-014-001 0: OFF 1: ON
1041
[Scan:FlairAPI Setting]
1-041-001 0x00 – 0xff
Sets Scanner FlairAPI Function enable / disable.
This SP is set by BitSwitch and needs to reboot the machine after making changes.
bit
Setting
bit 0
Start of FlairAPI Server
bit 1
Access permission of
FlairAPI from outside
of the machine
*CTL
[0 or 1 / 1 / 1/step]
0: Disable
1: Enable
*CTL
[0 or 1 / 0 / 1/step]
0: OFF
1: ON
*CTL
* see BitSwitch below:
meanings
0
1
Off
On
(Do not Start)
(Start)
Disabled
Enabled
Scanner Service Menu
Description
Sets whether to start exclusive
FlairAPI http server. If it is 0,
scanning FlairAPI function and
simple UI function will be
disabled.
If it is "0", accessing is limited
from the machine only, such as
operating panel, SDK/J, MFP
browsers etc... If it is "1",
accessing is allowed from
outside of FlairAPI such as PC,
Remote UI, IT-Box etc...
671

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244

Table of Contents