4.12.2. Other signals on the display

The following table summarizes that messages that may be shown on the dispaly panel
MESSAGE ON DISPLAY
off
fan acc
load wood
fire on
Eco Stop
20 C°
62 C°
UT 01, UT02,...
day1,,,7
set
Alar fan fail
stop fire
mcz spa
cool fire
alar dep fail
alarm smoke probe
alar no acc
alar no fire
alar fail sic

4.12.3. Lockout of the stove

The following things can cause the stove to lock out:
Overheating of the structure and of the pellet hopper
Overheating of the water in the boiler (T>85°C)
High pressure in the outlet fumes (as read by the pressure
switch) and therefore possible obstruction of the smoke
discharge system or external back-pressure.
Pressure in system less than or greater than the minimum or
maximum parameters of operation
The lockout is indicated by the LED (7) lighting up, accompanied by a
beep.
In this situation the shutdown cycle is automatically activated.
Once this process has started, any attempt to reset the system is
useless. The cause of the lockout is shown on the display (8).

Boiler bulb thermostat

4.12.3.1.
The stove goes into a safety ALARM state called "ALAR SIC FAIL" due
to the water temperature being too high.
MANUAL RESET THERMOSTAT
With the stove cold, in order to carry out the manual reset, you
must unscrew the cap of the thermostatic probe on the back and
press the red button to reset. You will hear a "click" of the
thermostat. Then put the protection cap back in place.
8.
Operation
INSTALLATION AND USE MANUAL
MEANING
The stove is off
Initial lighting sequence
Pellet loading
Lighting sequence and adjsutment/stabilizing of flame
The stove automatically shuts down upon reaching the temperature
Example of room temperature
Example of water temperature
user paramters for programming time, time periods, etc.
Days of the week
Setting of stove operating mode (e.g. SET MAN = Stove set to manual)
The smoke fan is not operating correctly
Automatic cleaning of the brazier in the set period of time
mcz spa
The stove is in cooling mode
The pressure switch has tripped, indicating difficulty in smoke expulsion
The smoke probe is not working correctly
An ignition attempt has failed.
There is no fire stove
Thermal alarm Excessive heat in the structure
PELLET STOVES
Figure 7 and
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
Chapter 4
Figure 7 - Touche de réarmement de la sonde à
boule
Figure 8 - Comment réarmer le thermostat à
boule une fois que le poêle est froid.
52
page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Athos power hydroNova

Table of Contents