Internal Thermostat - Position Of Internal Room Sensor; Operation By Means Of External Thermostat; Connection Of External Thermostat; Setting Of Eco-Stop Mode - MCZ Polar Installation And Use Manual

Table of Contents

Advertisement

4.10.2.1. Internal thermostat - Position of internal room sensor

Only when installation is complete, be sure to check that the
room probe is removed from its place and set far away from
the stove, to prevent it from detecting incorrect temperatures.
The probe is located on the back part of the stove.
When you use the internal thermostat, you should always set a
temperature that is a few degrees higher (for example, if you want to
attain 20°C you should set to 22°C) because the probe is affected by
the heat from the body of the stove.

4.10.2.2. Operation by means of external thermostat

EXTERNAL THERMOSTAT (not included with the stove, to be
provided by the user)
The temperature of the stove can also be controlled by an external
room thermostat. It is located in a central position of the room where
the stove is installed. It provides a closer match between the heating
temperature requested of the stove and what it actually provides.

4.10.2.3. Connection of external thermostat

Connect the two wires coming from the wall-mounted thermostat to the
terminal of the MCZ connector.
Insert the connector in the socket located on the back of the stove.
Figure 7
Once the thermostat is connected, you will need to
disconnect the internal thermostat that the stove is
equipped with.
In order to do this, proceed as follows:
Press the button
control panel. The display of the control panel will show the
message UT01/OFF
Press the button
UT16";
"
the display of the control panel shows UT16
Press and hold the button
"UT20"
to item
; the display will show the message UT19/OFF
Using the buttons
it is set to "ON", the internal thermostat is enabled. Conversely, if it
the parameter is set to "OFF", the external thermostat is enabled
and the internal one is disabled.
Therefore, if you need to enable the external thermostat, you will
need to set parameter "UT20" to "OFF".
To exit the menu, press the button

4.10.3. Setting of ECO-STOP mode

The thermostat manages stove operation by shutting the stove
down once the set temperature is reached and then lighting
again when this is necessary.
You can activate or de-activate this function, or select the intervals with
which the stove is to shut down.
Operation
INSTALLATION AND USE MANUAL
immediately followed by the button
repeatedly until the display on the panel shows
and then press the button
or
, set this parameter to "ON" or "OFF". If
or wait 60 seconds
PELLET STOVES
external thermostat
on the
and go
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
Internal room probe
Wiring from
Figure 7 - Connection of the serial connector of the
serial connector of the external thermostat in the socket
on the back of the stove
2
U t 20
!
SET
O FF
1
6
External thermostat enabled and internal thermostat
disabled
Chapter 4
41
page
MCZ serial
connector
3
5
4
TUR BO