Connections To The System; System Filling; Water Characteristics - MCZ Polar Installation And Use Manual

Table of Contents

Advertisement

3.4.1.

Connections to the system

Make the connections to the corresponding fittings shown in the
diagram on the previous page. Make sure the pipes are not placed
under tension or undersized.
IMPORTANT
IT IS STRONGLY RECOMMENDED TO WASH THE
ENTIRE SYSTEM BEFORE CONNECTING IT IN ORDER
TO GET RID OF RESIDUES AND DEPOSITS.
Upstream from the stove, always install shutters so
as to disconnect it from the plumbing system should
it be necessary to move it, or when it requires
routine and/or special maintenance.
Connect the stove using hoses so that the stove is
not too strictly connected to the system, and to allow
slight movements.
The pressure discharge pipe should be tentatively
placed in a pitcher or funnel to keep water from
wetting the floor or the structure in the event of
excessive pressure.
3.4.2.

System filling

To fill the system, the stove is equipped with a tap (D), with a non-
return valve, for manual filling of the heating system. During this
operation, any air in the system is released by the automatic vent valve
at the upper left of the boiler body (under the ceramic top).
To ensure the valve vents correctly, it is advisable to loosen the grey
cap one turn and to keep the red cap blocked
The
filling
pressure
1 bar.
During operation, if the system pressure drops (due to evaporation of
dissolved gases in the water) to values lower than the minimum
indicated above, the user must use the filling valve to bring the
pressure back up to its normal pressure.
For proper operation of the stove WHEN HOT, the pressure in the
boiler must be 1.5 bar.
To monitor the pressure of the system, install down the line
from the bibcock (D) a pressure gauge with a scale of 0-5 bar.
This is to be done by the installer.
Upon completion of this operation, always close the tap.
3.4.3.

Water characteristics

The characteristics of the water used to fill the system are very
important to prevent the build-up of mineral salts and the formation of
incrustations along the pipes, in the boiler and in the heat exchangers
(especially plate heat exchangers for the heating of domestic water -
see chapter 4.13)
Therefore,
please
CONCERNING:
Installation and assembly
INSTALLATION AND USE MANUAL
(see figure)
of
the
system
WHEN COLD
GET
YOUR
PLUMBER'S
PELLET STOVES
must be
ADVICE
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
Pressure discharge pipe (3 bar)
D
E
C
Filling tap (D)
Red plug blocked
Grey plug loosened
1 turn
Chapter 3