4.10.2. Operating modes

The AUTOMATIC mode lets you set a certain temperature to be
reached. In this operating mode the stove will automatically vary the
thermal power provided so as to keep the temperature in the room
constantly at the previously set value.
As previously described, the temperature is adjusted using the buttons
,
and
in steps of 1 degree centigrade.
Also front ventilation, which is active in automatic mode only when the
stove is hot, is divided into 5 speeds. It can be controlled using the
.
buttons
and
The speed of the fan will be shown for a few
seconds on the display (8).
This setting will be maintained at the next lighting.
Operating example:
If the ambient temperature measured by the local probe on the stove is
15°C, and the temperature set on the thermostat is 22°C, the stove will
sequentially go to maximum power. Upon reaching the requested fixed
temperature (22°C), the stove will go back to minimum power or it will
(See paragraph 4.9.3)
enter ECO-STOP mode
It must be remembered however that the temperature keyed into the
thermostat is only indicative, and it is up to the user to find the correct
setting in the location where the stove is installed (for example, to
achieve 22°C in the room, it may be necessary to set the thermostat on
the stove to 20°C). This is because the ambient thermostat is located
near the body of the stove; therefore, it detects the heat radiated from
the stove.
In this mode, lighting and shutdown are performed by the user, by
pressing button
for a few seconds.
It is advisable to inspect the contents of the hopper from time to time,
to keep the fire from going out due to lack of fuel.
ATTENTION!
If, while the stove is running, conditions occur which
modify the normal state of operation, the general
alarm LED (7) lights up, accompanied by an audible
'beep' (see the paragraph on "Lockout of the stove"),
and the stove reacts by starting the process of
complete shutdown.
In the event of an electrical power outage during
lighting or operation, the stove goes into a cooling-off
stage and later automatically relights itself.
Operation
PELLET STOVES
INSTALLATION AND USE MANUAL
2
SE T
!
SET
22°C
1
6
Adjustment of thermostat temperature (temperature to
be reached in the room)
2
AIR4
!
SET
22°C
1
6
Adjustment of the speed of the front fan
2
Al ar
!
SET
1
6
Stove in alarm and in lockout status
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
Chapter 4
40
page
3
5
4
TUR BO
3
5
4
TURBO
3
5
4
TURBO