Section 3

3.1 Restoring All data from Compact flash card

In the case of component exchange it will be necessary to reload the previ-
ously saved archives to achieve a functional machine.
The following steps should be carried out in order to reload the data previ-
ously stored on the CF card.
The controller should first be switched on and the password for the SER-
VICE should be set: The password for a new CNC component is always
the default "EVENING", this should be changed after new installation to
prevent mishandling of the system in the future.
Once the password is set the system should be switched OFF and ON and
the Startup menu entered with the SELECT key when prompted.
See picture below:
Startup Menu
Normal Startup
Reload saved user data
Startup with default data
PLC Stop
PLC overall reset / default PLC program
HMI Startup with default data
Remove drive data
Remove drive data/default data
Software update
Choose menu option "Startup with default data" and confirm with the
ENTER key.
The control will now make a new start, wait until the control is finished
starting up and once again enter the SERVICE password.
You should see the message "004060 Standard machine data is loaded".
Using copy from CF card and paste to CNC the backup data can be re-
stored to the control. See the following diagrams:
SINUMERIK 802D sl Operating and Service Training Manual
Restoring All data from Compact flash card