Check The Sequencing Cables; Check The Interlock System For Proper Operation - Genie AWP Super Series Service Manual

Hide thumbs Also See for AWP Super Series:
Table of Contents

Advertisement

September 2016
A-11 C hec k the Sequencing C abl es
A-11

Check the Sequencing Cables

Genie specifications require that this procedure be
performed every 8 hours or daily, whichever comes
first.
Detection of damage to sequencing cables or
components is essential for safe machine
operation. An unsafe working condition exists if the
sequencing components are damaged and do not
operate smoothly. A daily check of the sequencing
system allows the inspector to identify changes in
the operating condition that might indicate damage.
1
Visually inspect the cables and components
for the following:
• Frayed or broken wire strands
• Kinks in the cable
• Corrosion
• Paint or foreign materials
• Broken or damaged pulleys
• Unusual or excessive pulley wear
• Split or cracked threaded swage ends
2
Confirm the following:
• Cables are on the pulleys
• Upper and lower cable ends are properly
secured
• Upper and lower mounting brackets are
properly secured
Part No. 38139
A-12 C hec k the Interlock Sys tem for Pr oper Operation
A-12
Check the Interlock System for
Proper Operation
Genie specifications require that this procedure be
performed every 8 hours or daily, whichever comes
first.
Testing the interlock system for malfunctions is
essential for safe machine operation. An unsafe
working condition exists if any interlock display light
fails to operate properly.
AWPS models
1
2
AWP Super Series • IWP Super Series
Checklist A Procedures
Turn the key switch to ground control and pull
out the red Emergency Stop button to the
position. Twist to release the red Emergency
Stop button at the platform controls.
Result: AC & DC models: .The power should
be on.
Air models: The air pressure gauge should
read 80 - 110 psi / 5.5 - 7.8 bar
Slide each outrigger into a base socket until
the outrigger lock pin snaps into place. Adjust
outriggers to level using the outrigger screw
jack until the base casters are slightly off the
ground.
Service Manual